TY - JOUR
T1 - Effect of HF addition on the microwave-assisted acid-digestion for the determination of metals in coal by inductively coupled plasma-atomic emission spectrometry
AU - Xu, Yan Hua
AU - Iwashita, Akira
AU - Nakajima, Tsunenori
AU - Yamashita, Hiroyuki
AU - Takanashi, Hirokazu
AU - Ohki, Akira
PY - 2005/3/31
Y1 - 2005/3/31
N2 - The microwave-assisted acid-digestion for the determination of metals in coal by ICP-AES was investigated, especially focusing on the necessity of adding HF. By testing five certified reference materials, BCR-180, BCR-040, NIST-1632b, NIST-1632c, and SARM-20, it was found that the two-stage digestion without HF (HNO3 + H2O2 was used) was very effective for the pretreatment of ICP-AES measurement. Both major metals (Al, Ca, Fe, and Mg) and minor or trace metals (Co, Cr, Cu, Mn, Ni, Pb, and Zn) in coal gave good recoveries for their certified or reference values. The possibility of 'HF-memory effect' was cancelled by the use of a set of vessels which had been never contacted with HF. Twenty-four Japanese standard coals (SS coals) were analyzed by the present method, and the concentrations of major metals measured by the present method provided very high accordance with those from the authentic JIS (Japanese Industrial Standard) method.
AB - The microwave-assisted acid-digestion for the determination of metals in coal by ICP-AES was investigated, especially focusing on the necessity of adding HF. By testing five certified reference materials, BCR-180, BCR-040, NIST-1632b, NIST-1632c, and SARM-20, it was found that the two-stage digestion without HF (HNO3 + H2O2 was used) was very effective for the pretreatment of ICP-AES measurement. Both major metals (Al, Ca, Fe, and Mg) and minor or trace metals (Co, Cr, Cu, Mn, Ni, Pb, and Zn) in coal gave good recoveries for their certified or reference values. The possibility of 'HF-memory effect' was cancelled by the use of a set of vessels which had been never contacted with HF. Twenty-four Japanese standard coals (SS coals) were analyzed by the present method, and the concentrations of major metals measured by the present method provided very high accordance with those from the authentic JIS (Japanese Industrial Standard) method.
KW - Addition of HF
KW - Coal
KW - Inductively coupled plasma-atomic emission spectrometry
KW - Metal concentration
KW - Microwave-assisted digestion
KW - Trace metals
UR - http://www.scopus.com/inward/record.url?scp=15944366808&partnerID=8YFLogxK
U2 - 10.1016/j.talanta.2004.09.018
DO - 10.1016/j.talanta.2004.09.018
M3 - 文章
AN - SCOPUS:15944366808
SN - 0039-9140
VL - 66
SP - 58
EP - 64
JO - Talanta
JF - Talanta
IS - 1
ER -