TY - JOUR
T1 - Comparison of Four Rapid N-Glycan Analytical Methods and Great Application Potential in Cell Line Development
AU - Jin, Xiaoqing
AU - Chu, Jianlin
AU - He, Bingfang
N1 - Publisher Copyright:
© 2024 by the authors.
PY - 2024/8
Y1 - 2024/8
N2 - N-glycan, a critical quality attribute (CQA) of monoclonal antibodies, profoundly impacts potency, immunogenicity, safety, and clinical efficiency. Therefore, N-glycan should be monitored and controlled during development. The conventional 2-AB method is considered the gold standard for N-glycan analysis, which is labor intensive and time consuming. Moreover, its sample requirement is relatively high and cannot be met in early-stage development, including cell line development. In this study, we compared the performance of four rapid analytical methods in N-glycan analysis of mAbs, including the rapid 2-AB method, reduction method, off-line IdeS digestion method, and two-dimensional liquid chromatography-mass spectrometry (2D-LC-MS) method. Our results showed that these four rapid analytical methods could provide comparable N-glycan data. Moreover, these four rapid methods shortened the testing time for the conventional 2-AB method from days to just minutes. They also reduced the sample requirement for the conventional 2-AB method from milligrams to micrograms. Among these four rapid methods, the 2D-LC-MS method demonstrated great potential for applications in time-consuming cell line development because it required less testing time and a lower sample requirement.
AB - N-glycan, a critical quality attribute (CQA) of monoclonal antibodies, profoundly impacts potency, immunogenicity, safety, and clinical efficiency. Therefore, N-glycan should be monitored and controlled during development. The conventional 2-AB method is considered the gold standard for N-glycan analysis, which is labor intensive and time consuming. Moreover, its sample requirement is relatively high and cannot be met in early-stage development, including cell line development. In this study, we compared the performance of four rapid analytical methods in N-glycan analysis of mAbs, including the rapid 2-AB method, reduction method, off-line IdeS digestion method, and two-dimensional liquid chromatography-mass spectrometry (2D-LC-MS) method. Our results showed that these four rapid analytical methods could provide comparable N-glycan data. Moreover, these four rapid methods shortened the testing time for the conventional 2-AB method from days to just minutes. They also reduced the sample requirement for the conventional 2-AB method from milligrams to micrograms. Among these four rapid methods, the 2D-LC-MS method demonstrated great potential for applications in time-consuming cell line development because it required less testing time and a lower sample requirement.
KW - 2D-LC-MS
KW - monoclonal antibody
KW - N-glycan
UR - http://www.scopus.com/inward/record.url?scp=85202431050&partnerID=8YFLogxK
U2 - 10.3390/app14167320
DO - 10.3390/app14167320
M3 - 文章
AN - SCOPUS:85202431050
SN - 2076-3417
VL - 14
JO - Applied Sciences (Switzerland)
JF - Applied Sciences (Switzerland)
IS - 16
M1 - 7320
ER -