TY - JOUR
T1 - Cyclometalated iridium(III) complexes containing bithiazole ligands for preferable viscosity detection
AU - Yin, Jianrong
AU - Tao, Tao
AU - Ou, Changjin
AU - Shao, Jinjun
AU - Huang, Wei
N1 - Publisher Copyright:
© 2022 Elsevier Ltd
PY - 2022/9
Y1 - 2022/9
N2 - Detecting viscosity is vital for pathological investigation since subtle changes in cellular microviscosity are related to pathologies and diseases. In this work, five cationic Ir(III) complexes Ir1–Ir5 with the formulas as [Ir(ppy)2L]PF6 have been synthesized, where L1-L5 are a family of coplanar bithiazole derivatives having versatile donor/acceptor tails (proton, bromo, tetraphenylethylene, benzothiophene, ethyl benzoate). Fluorescent experiment shows that L1-L5 have a fluorescent activity with high quantum yields (Ф > 33%). However, the quantum yields of Ir1–Ir5 are weak in the range from 2.7% to 7.7%. There is a linear relationship between Log(I620 nm) and Log(viscosity), which can quantitatively measure viscosity in the range of 1.36–669 cP. Furthermore, a cell colocalization experiment has been performed using commercial nuclear dye (DAPI), lysosomal dye (LysoGreen), and mitochondrial dye (MitoGreen) to explore the subcellular localization ability of Ir1 in living cells, indicating that the probe Ir1 can easily pass through the cell membrane, and can accurately target lysosomes in living cells. In addition, complex Ir1 can quantitatively detect viscosity and target lysosomes, possessing the potential for practical application in intracellular viscosity detection.
AB - Detecting viscosity is vital for pathological investigation since subtle changes in cellular microviscosity are related to pathologies and diseases. In this work, five cationic Ir(III) complexes Ir1–Ir5 with the formulas as [Ir(ppy)2L]PF6 have been synthesized, where L1-L5 are a family of coplanar bithiazole derivatives having versatile donor/acceptor tails (proton, bromo, tetraphenylethylene, benzothiophene, ethyl benzoate). Fluorescent experiment shows that L1-L5 have a fluorescent activity with high quantum yields (Ф > 33%). However, the quantum yields of Ir1–Ir5 are weak in the range from 2.7% to 7.7%. There is a linear relationship between Log(I620 nm) and Log(viscosity), which can quantitatively measure viscosity in the range of 1.36–669 cP. Furthermore, a cell colocalization experiment has been performed using commercial nuclear dye (DAPI), lysosomal dye (LysoGreen), and mitochondrial dye (MitoGreen) to explore the subcellular localization ability of Ir1 in living cells, indicating that the probe Ir1 can easily pass through the cell membrane, and can accurately target lysosomes in living cells. In addition, complex Ir1 can quantitatively detect viscosity and target lysosomes, possessing the potential for practical application in intracellular viscosity detection.
KW - Aggregation-induced emission
KW - Bithiazole
KW - Iridium(III)
KW - Metal complexes
KW - Viscosity detection
UR - http://www.scopus.com/inward/record.url?scp=85133456567&partnerID=8YFLogxK
U2 - 10.1016/j.dyepig.2022.110512
DO - 10.1016/j.dyepig.2022.110512
M3 - 文章
AN - SCOPUS:85133456567
SN - 0143-7208
VL - 205
JO - Dyes and Pigments
JF - Dyes and Pigments
M1 - 110512
ER -