Macroscopic morphology observation, chemical composition analysis, corrosion product energy spectrum and X-ray diffraction analysis and microstructure inspection were used to analyze the failure reasons of a 10#steel U-shaped heat exchange tube run in a plant for about half a year. The results show that the fouling on the outer wall of the U-tube was serious and the corrosion under the scale occurred. At the same time, the enrichment of Cl-in the occlusion zone under the scale and the “autocatalytic acidification” effect accelerated the progress of corrosion under the scale, resulting in leakage of the heat exchange tube within half a year.
Original language | English |
---|---|
Article number | 1005-748X(2019)05-0332-04 |
Pages (from-to) | 332-335 |
Number of pages | 4 |
Journal | Corrosion and Protection |
Volume | 40 |
Issue number | 5 |
DOIs | |
State | Published - May 2019 |
Keywords
- 10steel
- Cl
- Failure
- Heat exchanger
- Under-depost corrosion