TY - JOUR
T1 - Heat Transfer Study from a Salty Droplet Film on a Horizontal Tube in Mechanical Vapor Recompression Crystallization System
AU - Cao, Yanmei
AU - Wang, Yu
AU - Gao, Yang
AU - Kosonen, Risto
N1 - Publisher Copyright:
© 2022 by the authors.
PY - 2022/7
Y1 - 2022/7
N2 - The horizontal drop film evaporator is a key component of the mechanical vapor recompression crystallization system, which can be used to evaporate effluent and recycle secondary vapor energy. However, the properties of heat transfer and flow of the salty effluent sprayed external of the horizontal drop film evaporation tube are obviously different from that of ordinary water. We established a 3D model for a horizontal drop film evaporator in the system, and water and sodium sulfate mixture were manufactured to reproduce the real salty effluent. By applying the VOF (volume of fluid) model, the liquid-gas interface of a salty effluent spray drop film formed on a horizontal tube in the evaporator was traced. The impacts of various heat flux, sodium sulfate content, spray density, and temperature on the local Nusselt number were studied, and a dimensionless correlation was established. The results showed that the effect of surface tension cannot be negligible; as the sodium sulfate content rises, the local Nusselt number declines in the thermal developing region; as the spray temperature and density rises, the local Nusselt number rises, which was largely independent of the heat flux in the thermal developing region.
AB - The horizontal drop film evaporator is a key component of the mechanical vapor recompression crystallization system, which can be used to evaporate effluent and recycle secondary vapor energy. However, the properties of heat transfer and flow of the salty effluent sprayed external of the horizontal drop film evaporation tube are obviously different from that of ordinary water. We established a 3D model for a horizontal drop film evaporator in the system, and water and sodium sulfate mixture were manufactured to reproduce the real salty effluent. By applying the VOF (volume of fluid) model, the liquid-gas interface of a salty effluent spray drop film formed on a horizontal tube in the evaporator was traced. The impacts of various heat flux, sodium sulfate content, spray density, and temperature on the local Nusselt number were studied, and a dimensionless correlation was established. The results showed that the effect of surface tension cannot be negligible; as the sodium sulfate content rises, the local Nusselt number declines in the thermal developing region; as the spray temperature and density rises, the local Nusselt number rises, which was largely independent of the heat flux in the thermal developing region.
KW - local Nusselt number
KW - mechanical vapor recompression system
KW - numerical simulation
KW - salty effluent
KW - spray drop film
UR - http://www.scopus.com/inward/record.url?scp=85136391913&partnerID=8YFLogxK
U2 - 10.3390/en15145109
DO - 10.3390/en15145109
M3 - 文章
AN - SCOPUS:85136391913
SN - 1996-1073
VL - 15
JO - Energies
JF - Energies
IS - 14
M1 - 5109
ER -