TY - JOUR
T1 - Seismic performance of recycled concrete-filled square steel tube columns
AU - Chen, Zongping
AU - Jing, Chenggui
AU - Xu, Jinjun
AU - Zhang, Xianggang
N1 - Publisher Copyright:
© 2017, Institute of Engineering Mechanics, China Earthquake Administration and Springer-Verlag Berlin Heidelberg.
PY - 2017/1/1
Y1 - 2017/1/1
N2 - An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance.
AB - An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance.
KW - column
KW - cyclic loading
KW - recycled concrete-filled square steel tube (RCFST)
KW - replacement percentage
KW - seismic performance
UR - http://www.scopus.com/inward/record.url?scp=85010651503&partnerID=8YFLogxK
U2 - 10.1007/s11803-017-0372-2
DO - 10.1007/s11803-017-0372-2
M3 - 文章
AN - SCOPUS:85010651503
SN - 1671-3664
VL - 16
SP - 119
EP - 130
JO - Earthquake Engineering and Engineering Vibration
JF - Earthquake Engineering and Engineering Vibration
IS - 1
ER -