TY - JOUR
T1 - Stretchable Ti3C2Tx MXene/Carbon Nanotube Composite Based Strain Sensor with Ultrahigh Sensitivity and Tunable Sensing Range
AU - Cai, Yichen
AU - Shen, Jie
AU - Ge, Gang
AU - Zhang, Yizhou
AU - Jin, Wanqin
AU - Huang, Wei
AU - Shao, Jinjun
AU - Yang, Jian
AU - Dong, Xiaochen
N1 - Publisher Copyright:
© 2017 American Chemical Society.
PY - 2018/1/23
Y1 - 2018/1/23
N2 - It remains challenging to fabricate strain-sensing materials and exquisite geometric constructions for integrating extraordinary sensitivity, low strain detectability, high stretchability, tunable sensing range, and thin device dimensions into a single type of strain sensor. A percolation network based on Ti3C2Tx MXene/carbon nanotube (CNT) composites was rationally designed and fabricated into versatile strain sensors. This weaving architecture with excellent electric properties combined the sensitive two-dimensional (2D) Ti3C2Tx MXene nanostacks with conductive and stretchable one-dimensional (1D) CNT crossing. The resulting strain sensor can be used to detect both tiny and large deformations with an ultralow detection limit of 0.1% strain, high stretchability (up to 130%), high sensitivity (gauge factor up to 772.6), tunable sensing range (30% to 130% strain), thin device dimensions (<2 μm), and excellent reliability and stability (>5000 cycles). The versatile and scalable Ti3C2Tx MXene/CNT strain sensors provide a promising route to future wearable artificial intelligence with comprehensive tracking ability of real-time and in situ physiological signals for health and sporting applications.
AB - It remains challenging to fabricate strain-sensing materials and exquisite geometric constructions for integrating extraordinary sensitivity, low strain detectability, high stretchability, tunable sensing range, and thin device dimensions into a single type of strain sensor. A percolation network based on Ti3C2Tx MXene/carbon nanotube (CNT) composites was rationally designed and fabricated into versatile strain sensors. This weaving architecture with excellent electric properties combined the sensitive two-dimensional (2D) Ti3C2Tx MXene nanostacks with conductive and stretchable one-dimensional (1D) CNT crossing. The resulting strain sensor can be used to detect both tiny and large deformations with an ultralow detection limit of 0.1% strain, high stretchability (up to 130%), high sensitivity (gauge factor up to 772.6), tunable sensing range (30% to 130% strain), thin device dimensions (<2 μm), and excellent reliability and stability (>5000 cycles). The versatile and scalable Ti3C2Tx MXene/CNT strain sensors provide a promising route to future wearable artificial intelligence with comprehensive tracking ability of real-time and in situ physiological signals for health and sporting applications.
KW - MXene
KW - artificial electronic skin
KW - carbon nanotubes
KW - controllable sensing range
KW - ultrasensitivity
UR - http://www.scopus.com/inward/record.url?scp=85042197069&partnerID=8YFLogxK
U2 - 10.1021/acsnano.7b06251
DO - 10.1021/acsnano.7b06251
M3 - 文章
C2 - 29202226
AN - SCOPUS:85042197069
SN - 1936-0851
VL - 12
SP - 56
EP - 62
JO - ACS Nano
JF - ACS Nano
IS - 1
ER -