TY - JOUR
T1 - Ultrasensitive determination of intracellular hydrogen peroxide by equipping quantum dots with a sensing layer via self-passivation
AU - Hu, Xixi
AU - Liu, Jia
AU - Jin, Haozhe
AU - Huang, Fei
AU - Wang, Zhaoyin
AU - Wang, Fang
AU - Dai, Zhihui
N1 - Publisher Copyright:
© 2022, Tsinghua University Press.
PY - 2022/5
Y1 - 2022/5
N2 - Abnormal expression of hydrogen peroxide (H2O2) indicates the disorder of cell functions and is able to induce the occurrence and deterioration of numerous diseases. However, limited by its low concentration under pathophysiological conditions, intracellular H2O2 is still difficult to be determined to date. Herein, to achieve sensitive quantification of H2O2 in cells, CIS/ZnS/ZnS quantum dots (CIS/d-ZnS QDs) are retrofitted with ZnO shells via self-passivation. Different from the traditional self-passivation of QDs, self-passivation of CIS/d-ZnS QDs is realized facilely without the assistance of additional cation ions, which improves optical properties of QDs and equips the QDs with a sensing layer. As a result, the CIS/d-ZnS/ZnO QDs exhibit enhanced fluorescence emission and stability. Relying on the decomposition of ZnO and ZnS shells in the presence of H2O2, aggregated QDs reveal exciton energy transfer effect, resulting in fluorescence quenching. On a basis of this principle, a fluorescence H2O2 sensor is further established with the CIS/d-ZnS/ZnO QDs. To be noted, since the equipped ZnO shells are more susceptible to H2O2 than original ZnS shells, analytical performance of the fluorescence sensor is remarkably promoted by the self-passivation of QDs. Accordingly, H2O2 can be measured in 5 orders of magnitude with a limit of detection (LOD) of 0.46 nM. Furthermore, because the ZnO shells improve H2O2-responsive selectivity and sensitivity, variation of H2O2 in cells can also be quantified with the CIS/d-ZnS/ZnO QDs. In this work, sensitive detection of intracellular H2O2 is enabled by equipping QDs with a sensing layer, which provides an alternative perspective of functionalizing nanomaterials for analytical applications. [Figure not available: see fulltext.]
AB - Abnormal expression of hydrogen peroxide (H2O2) indicates the disorder of cell functions and is able to induce the occurrence and deterioration of numerous diseases. However, limited by its low concentration under pathophysiological conditions, intracellular H2O2 is still difficult to be determined to date. Herein, to achieve sensitive quantification of H2O2 in cells, CIS/ZnS/ZnS quantum dots (CIS/d-ZnS QDs) are retrofitted with ZnO shells via self-passivation. Different from the traditional self-passivation of QDs, self-passivation of CIS/d-ZnS QDs is realized facilely without the assistance of additional cation ions, which improves optical properties of QDs and equips the QDs with a sensing layer. As a result, the CIS/d-ZnS/ZnO QDs exhibit enhanced fluorescence emission and stability. Relying on the decomposition of ZnO and ZnS shells in the presence of H2O2, aggregated QDs reveal exciton energy transfer effect, resulting in fluorescence quenching. On a basis of this principle, a fluorescence H2O2 sensor is further established with the CIS/d-ZnS/ZnO QDs. To be noted, since the equipped ZnO shells are more susceptible to H2O2 than original ZnS shells, analytical performance of the fluorescence sensor is remarkably promoted by the self-passivation of QDs. Accordingly, H2O2 can be measured in 5 orders of magnitude with a limit of detection (LOD) of 0.46 nM. Furthermore, because the ZnO shells improve H2O2-responsive selectivity and sensitivity, variation of H2O2 in cells can also be quantified with the CIS/d-ZnS/ZnO QDs. In this work, sensitive detection of intracellular H2O2 is enabled by equipping QDs with a sensing layer, which provides an alternative perspective of functionalizing nanomaterials for analytical applications. [Figure not available: see fulltext.]
KW - fluorescence imaging
KW - hydrogen peroxide
KW - quantum dot
KW - self-passivation
KW - ultrasensitive analysis
UR - http://www.scopus.com/inward/record.url?scp=85124083922&partnerID=8YFLogxK
U2 - 10.1007/s12274-022-4099-7
DO - 10.1007/s12274-022-4099-7
M3 - 文章
AN - SCOPUS:85124083922
SN - 1998-0124
VL - 15
SP - 4350
EP - 4356
JO - Nano Research
JF - Nano Research
IS - 5