TY - JOUR
T1 - A Novel fluorescent probe for copper ions based on polymer-modified CdSe/CdS Core/shell quantum dots
AU - Cao, Zhong
AU - Gu, Zheng
AU - Zeng, Ju Lan
AU - Liu, Jin Hua
AU - Deng, Qin
AU - Fan, Jun Bing
AU - Xiang, Jian Nan
PY - 2011
Y1 - 2011
N2 - Quantum dots (QDs) have become one of the most attractive fields of current research because of their unique optical properties. Novel copper-sensitive fluorescent fluoroionophores based on CdSe/CdS core/shell QDs modified with a polymer of MAO-mPEG were synthesized and characterized in the present work. A pH of 6.47 was optimally selected for measurements. By modifying QDs with MAO-mPEG, significant aqueous fluorescence quenching was observed upon binding with copper ions involving both reduced and oxidized environments, indicating great sensitivity and specificity for copper-ion sensing. No significant interfering effects from other metal ions, such as Ag+, Al3+, Ba2+, Ca2+, Cd2+, Co2+, Cr3+, Fe2+, Fe3+, Hg2+, K+, Mg2+, Mn2+, Na+, Ni2+, Pb2+, Sn2+, and Zn2+, were observed. The linear response range for Cu2+ was found to be 0.01 - 0.50 μM, and the limit of detection was evaluated to be 16 nM. The proposed method demonstrated improved sensitivity and selectivity characteristics for Cu(II) determinations based on CdSe/CdS core/shell QDs modified with MAO-mPEG by using a typical liquid-phase quenching assay, showing its potential application to multiplex sensing of different analytes through distinct ligand conjugation and functionalization of individual fluorophores. 2011
AB - Quantum dots (QDs) have become one of the most attractive fields of current research because of their unique optical properties. Novel copper-sensitive fluorescent fluoroionophores based on CdSe/CdS core/shell QDs modified with a polymer of MAO-mPEG were synthesized and characterized in the present work. A pH of 6.47 was optimally selected for measurements. By modifying QDs with MAO-mPEG, significant aqueous fluorescence quenching was observed upon binding with copper ions involving both reduced and oxidized environments, indicating great sensitivity and specificity for copper-ion sensing. No significant interfering effects from other metal ions, such as Ag+, Al3+, Ba2+, Ca2+, Cd2+, Co2+, Cr3+, Fe2+, Fe3+, Hg2+, K+, Mg2+, Mn2+, Na+, Ni2+, Pb2+, Sn2+, and Zn2+, were observed. The linear response range for Cu2+ was found to be 0.01 - 0.50 μM, and the limit of detection was evaluated to be 16 nM. The proposed method demonstrated improved sensitivity and selectivity characteristics for Cu(II) determinations based on CdSe/CdS core/shell QDs modified with MAO-mPEG by using a typical liquid-phase quenching assay, showing its potential application to multiplex sensing of different analytes through distinct ligand conjugation and functionalization of individual fluorophores. 2011
UR - http://www.scopus.com/inward/record.url?scp=79959245809&partnerID=8YFLogxK
U2 - 10.2116/analsci.27.643
DO - 10.2116/analsci.27.643
M3 - 文章
AN - SCOPUS:79959245809
SN - 0910-6340
VL - 27
SP - 643
EP - 647
JO - Analytical Sciences
JF - Analytical Sciences
IS - 6
ER -