TY - JOUR
T1 - A rapid and ultrasensitive cardiac troponin I aptasensor based on an ion-sensitive field-effect transistor with extended gate
AU - Zhang, Wei
AU - Jiang, Jidong
AU - Liu, Tao
AU - Wang, Xun
AU - Wang, Yiqing
AU - Chu, Zhenyu
AU - Jin, Wanqin
N1 - Publisher Copyright:
© 2024 Elsevier B.V.
PY - 2024/9/1
Y1 - 2024/9/1
N2 - Acute myocardial infarction (AMI) is a life-threatening disease with a short course and a high mortality rate. However, it is still a great challenge to achieve the on-site diagnosis of this disease within minutes, meaning there is an urgent need to develop an efficient technology for realizing the rapid diagnosis and early warning of AMI in clinical emergencies. In this study, an ultrasensitive electrochemical aptasensor based on an extended-gate ion-sensitive field-effect transistor (EGISFET) was designed to achieve the quantitative assay of cardiac troponin I (cTnI), which is a highly sensitive and specific biomarker of AMI, within only 5 min. The EGISFET exhibits extremely high detection sensitivity due to its separated structure with a large sensing area and the surface-modified Prussian blue-gold nanoparticles (PB-AuNPs) composite, which serves as a signal magnifier and DNA loading platform for good electrocatalytic ability with a large specific area. Additionally, a target-induced strand-release strategy is proposed to shorten the recognition time of cTnI using a particular DNA strand. Under optimal conditions, the as-prepared aptasensor exhibits a wide linear range of 1–1000 pg/mL, an ultralow detection limit of 0.3 pg/mL, and reliable detection results in real serum samples. It is highly anticipated that this EGISFET-based aptasensor will have broad applications in the early warning and rapid diagnosis of AMI and other acute diseases in emergency treatment.
AB - Acute myocardial infarction (AMI) is a life-threatening disease with a short course and a high mortality rate. However, it is still a great challenge to achieve the on-site diagnosis of this disease within minutes, meaning there is an urgent need to develop an efficient technology for realizing the rapid diagnosis and early warning of AMI in clinical emergencies. In this study, an ultrasensitive electrochemical aptasensor based on an extended-gate ion-sensitive field-effect transistor (EGISFET) was designed to achieve the quantitative assay of cardiac troponin I (cTnI), which is a highly sensitive and specific biomarker of AMI, within only 5 min. The EGISFET exhibits extremely high detection sensitivity due to its separated structure with a large sensing area and the surface-modified Prussian blue-gold nanoparticles (PB-AuNPs) composite, which serves as a signal magnifier and DNA loading platform for good electrocatalytic ability with a large specific area. Additionally, a target-induced strand-release strategy is proposed to shorten the recognition time of cTnI using a particular DNA strand. Under optimal conditions, the as-prepared aptasensor exhibits a wide linear range of 1–1000 pg/mL, an ultralow detection limit of 0.3 pg/mL, and reliable detection results in real serum samples. It is highly anticipated that this EGISFET-based aptasensor will have broad applications in the early warning and rapid diagnosis of AMI and other acute diseases in emergency treatment.
KW - Cardiac troponin I assay
KW - Extended gate structure
KW - Ion-sensitive field-effect transistor
KW - PB-AuNPs composite
KW - Real serum detection
UR - http://www.scopus.com/inward/record.url?scp=85195393879&partnerID=8YFLogxK
U2 - 10.1016/j.talanta.2024.126364
DO - 10.1016/j.talanta.2024.126364
M3 - 文章
C2 - 38861763
AN - SCOPUS:85195393879
SN - 0039-9140
VL - 277
JO - Talanta
JF - Talanta
M1 - 126364
ER -