TY - JOUR
T1 - Design and characteristics investigation of a miniature low-temperature plasma spark discharge device
AU - Li, Xue
AU - Zhou, Renwu
AU - Zhang, Bo
AU - Zhou, Rusen
AU - Ostrikov, Ken
AU - Fang, Zhi
N1 - Publisher Copyright:
© 2019 Hefei Institutes of Physical Science, Chinese Academy of Sciences and IOP Publishing.
PY - 2019/3/1
Y1 - 2019/3/1
N2 - Atmospheric pressure low-temperature plasma is a promising tool in biomedicine applications including blood coagulation, bacterial inactivation, sterilization, and cancer treatment, due to its high chemical activity and limited thermal damage. It is of great importance to develop portable plasma sources that are safe to human touch and suitable for outdoor and household operation. In this work, a portable and rechargeable low-temperature plasma spark discharge device (130 mm ×80 mm ×35 mm, 300 g) was designed. The discharge frequency and plume length were optimized by the selection of resistance, capacitance, electrode gap, and ground electrode aperture. Results show that the spark plasma plume is generated with a length of 12 mm and a frequency of 10 Hz at a capacitance of 0.33 μF, resistance of 1 MΩ, electrode gap of 2 mm, and ground electrode aperture of 1.5 mm. Biological tests indicate that the plasma produced by this device contains abundant reactive species, which can be applied in plasma biomedicine, including daily sterilization and wound healing.
AB - Atmospheric pressure low-temperature plasma is a promising tool in biomedicine applications including blood coagulation, bacterial inactivation, sterilization, and cancer treatment, due to its high chemical activity and limited thermal damage. It is of great importance to develop portable plasma sources that are safe to human touch and suitable for outdoor and household operation. In this work, a portable and rechargeable low-temperature plasma spark discharge device (130 mm ×80 mm ×35 mm, 300 g) was designed. The discharge frequency and plume length were optimized by the selection of resistance, capacitance, electrode gap, and ground electrode aperture. Results show that the spark plasma plume is generated with a length of 12 mm and a frequency of 10 Hz at a capacitance of 0.33 μF, resistance of 1 MΩ, electrode gap of 2 mm, and ground electrode aperture of 1.5 mm. Biological tests indicate that the plasma produced by this device contains abundant reactive species, which can be applied in plasma biomedicine, including daily sterilization and wound healing.
KW - low-temperature plasma
KW - plasma medicine
KW - plasma source
KW - portable
KW - spark discharge
UR - http://www.scopus.com/inward/record.url?scp=85065844428&partnerID=8YFLogxK
U2 - 10.1088/2058-6272/aaf111
DO - 10.1088/2058-6272/aaf111
M3 - 文章
AN - SCOPUS:85065844428
SN - 1009-0630
VL - 21
JO - Plasma Science and Technology
JF - Plasma Science and Technology
IS - 5
M1 - 054005
ER -