摘要
316L stainless steel has good resistance to pitting corrosion, but pitting failure can also occur under certain conditions. The reasons for the leakage of an unused 316L heating furnace tube were analyzed by macro analysis’ chemical composition analysis’ electron scanning microscopy (SEM) ’ energy dispersive spectroscopy (EDS) and microstructure analysis. The results show that many Cl- and Br- ions were contained in the water used in hydraulic pressure test for the tube. After hydraulic pressure test, the tube was sealed before the water had been drained completely, resulting in the occurrence of pitting corrosion in storage period.
源语言 | 英语 |
---|---|
文章编号 | 1005-748X(2018)10-0810-04 |
页(从-至) | 810-813 |
页数 | 4 |
期刊 | Corrosion and Protection |
卷 | 39 |
期 | 10 |
DOI | |
出版状态 | 已出版 - 1 10月 2018 |