TY - JOUR
T1 - Glucose biosensor based on three dimensional ordered macroporous self-doped polyaniline/Prussian blue bicomponent film
AU - Chen, Xiaojun
AU - Chen, Zixuan
AU - Tian, Rong
AU - Yan, Wei
AU - Yao, Cheng
PY - 2012/4/20
Y1 - 2012/4/20
N2 - In this paper, a three dimensional ordered macroporous self-doped polyaniline/Prussian blue (3DOM SPAN/PB) bicomponent film was fabricated via the inverted crystal template technique using step-by-step electrodeposition. In this bicomponent film, PB not only acted as a redox mediator, but also presented increased stability in neutral or weak alkaline solution by the protection of SPAN layer on the top. A novel glucose biosensor was fabricated based on the large active surface area and excellent conductivity possessed by the 3DOM SPAN/PB film. The applying experimental conditions of the glucose biosensor have been optimized. Under the optimal conditions, the biosensor showed a wide linear range over three orders of magnitude in glucose concentrations (from 2 to 1600. μM) and a low detection limit of 0.4. μM. Moreover, the biosensor exhibited short response time, high selectivity and excellent operation stability, which can be applied to detect the blood sugar in real samples without any pretreatment.
AB - In this paper, a three dimensional ordered macroporous self-doped polyaniline/Prussian blue (3DOM SPAN/PB) bicomponent film was fabricated via the inverted crystal template technique using step-by-step electrodeposition. In this bicomponent film, PB not only acted as a redox mediator, but also presented increased stability in neutral or weak alkaline solution by the protection of SPAN layer on the top. A novel glucose biosensor was fabricated based on the large active surface area and excellent conductivity possessed by the 3DOM SPAN/PB film. The applying experimental conditions of the glucose biosensor have been optimized. Under the optimal conditions, the biosensor showed a wide linear range over three orders of magnitude in glucose concentrations (from 2 to 1600. μM) and a low detection limit of 0.4. μM. Moreover, the biosensor exhibited short response time, high selectivity and excellent operation stability, which can be applied to detect the blood sugar in real samples without any pretreatment.
KW - Biosensor
KW - Glucose oxidase
KW - Prussian blue
KW - Self-doped polyaniline
KW - Three dimensional ordered macroporous
UR - http://www.scopus.com/inward/record.url?scp=84862821542&partnerID=8YFLogxK
U2 - 10.1016/j.aca.2012.02.032
DO - 10.1016/j.aca.2012.02.032
M3 - 文章
C2 - 22444579
AN - SCOPUS:84862821542
SN - 0003-2670
VL - 723
SP - 94
EP - 100
JO - Analytica Chimica Acta
JF - Analytica Chimica Acta
ER -