TY - JOUR
T1 - Highly Sensitive Amperometric α -Ketoglutarate Biosensor Based on Reduced Graphene Oxide-Gold Nanocomposites
AU - Peng, Gang
AU - Yu, Yadong
AU - Chen, Xiaojun
AU - Huang, He
N1 - Publisher Copyright:
© 2020 Gang Peng et al.
PY - 2020
Y1 - 2020
N2 - Herein, a rapid and highly sensitive amperometric biosensor for the detection of α-ketoglutarate (α-KG) was constructed via an electrochemical approach, in which the glutamate dehydrogenase (GLUD) was modified on the surface of reduced graphene oxide-gold nanoparticle composite (rGO-Aunano composite). The rGO-Aunano composite was one-step electrodeposited onto glassy carbon electrode (GCE) surface and was characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and electrochemical techniques. In addition, the rGO-Aunano/GCE was also found to electrocatalyze the oxidation of β-nicotinamide adenine dinucleotide (NADH) at the peak potential of 0.3 V, which was negatively shifted compared with that at bare GCE or Aunano/GCE, illustrating better catalytic performance of rGO-Aunano. After the modification of GLUD, the GLUD/rGO-Aunano/GCE led to effective amperometric detection of α-KG through monitoring the NADH consumption and displayed a linear response in the range of 66.7 and 494.5 μM, with the detection limit of 9.2 μM. Moreover, the prepared GLUD/rGO-Aunano/GCE was further evaluated to be highly selective and used to test α-KG in human serum samples. The recovery and the RSD values were calculated in the range of 97.9-102.4% and 3.8-4.5%, respectively, showing a great prospect for its real application.
AB - Herein, a rapid and highly sensitive amperometric biosensor for the detection of α-ketoglutarate (α-KG) was constructed via an electrochemical approach, in which the glutamate dehydrogenase (GLUD) was modified on the surface of reduced graphene oxide-gold nanoparticle composite (rGO-Aunano composite). The rGO-Aunano composite was one-step electrodeposited onto glassy carbon electrode (GCE) surface and was characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and electrochemical techniques. In addition, the rGO-Aunano/GCE was also found to electrocatalyze the oxidation of β-nicotinamide adenine dinucleotide (NADH) at the peak potential of 0.3 V, which was negatively shifted compared with that at bare GCE or Aunano/GCE, illustrating better catalytic performance of rGO-Aunano. After the modification of GLUD, the GLUD/rGO-Aunano/GCE led to effective amperometric detection of α-KG through monitoring the NADH consumption and displayed a linear response in the range of 66.7 and 494.5 μM, with the detection limit of 9.2 μM. Moreover, the prepared GLUD/rGO-Aunano/GCE was further evaluated to be highly selective and used to test α-KG in human serum samples. The recovery and the RSD values were calculated in the range of 97.9-102.4% and 3.8-4.5%, respectively, showing a great prospect for its real application.
UR - http://www.scopus.com/inward/record.url?scp=85089798781&partnerID=8YFLogxK
U2 - 10.1155/2020/4901761
DO - 10.1155/2020/4901761
M3 - 文章
AN - SCOPUS:85089798781
SN - 1687-8760
VL - 2020
JO - International Journal of Analytical Chemistry
JF - International Journal of Analytical Chemistry
M1 - 4901761
ER -