Hydrophilic wire gauze packing in a wet scrubber column with extremely low liquid spray density for air detritiation: Experiment and CFD analysis

Fei Jiang, Changan Chen, Peilong Li, Yefei Liu, Bin Yu, Min Chen, Yan Shi, Jiangfeng Song

科研成果: 期刊稿件文章同行评审

摘要

The wet scrubber column for air detritiation required operation with very low liquid spray densities (0.02 to 0.5 m3/(m2⋅h)), which posed a considerable challenge in developing suitable structured packings. The hydrophilic modification of the phosphor-bronze wires was achieved by growing copper oxide nanowires on the wire surface. Compared to the original wire, the double-layer wire gauze with hydrophilic CuO coating exhibited more sufficient spreading. The VOF model effectively simulated the water droplets on the wire gauze and demonstrated that the liquid film formed within the wire sheets reduced flow disturbance between the two wet wire sheets. Experimental results confirmed that the wet pressure drop was significantly lower than the dry pressure drop, due to the sufficient wetting of the packings. The study provided valuable insights into the development of wire gauze packing, which is beneficial for further enhancing the performance of wet scrubber columns for air detritiation.

源语言英语
文章编号121466
期刊Chemical Engineering Science
309
DOI
出版状态已出版 - 1 5月 2025

指纹

探究 'Hydrophilic wire gauze packing in a wet scrubber column with extremely low liquid spray density for air detritiation: Experiment and CFD analysis' 的科研主题。它们共同构成独一无二的指纹。