TY - JOUR
T1 - Numerical study on thermohydraulic behavior in evaporator section of wicked copper-water heat pipe at low superheat
AU - Zhu, Xidong
AU - Dong, Yu
AU - Cheng, Jianjie
AU - Yao, Yao
AU - Bao, Jun
AU - Wang, Yu
AU - Liu, Jinxiang
N1 - Publisher Copyright:
© Published under licence by IOP Publishing Ltd.
PY - 2021/3/10
Y1 - 2021/3/10
N2 - Previous numerical studies have focused on the temperature profiles, flow pattern, heat transfer characteristics and transient behavior of wickless heat pipes. With the increase of heat dissipated power, the heat transfer capacity of the wickless heat pipe is no longer satisfied. Therefore, the research on flow and heat transfer of wicked heat pipe is more meaningful. In this paper, the numerical model of the heat pipe evaporator with a simplified rectangular wick structure was simulated. The present work to be aimed at the numerical model investigating on possible heat transfer performance. The effects of wick thickness, wick porosity, contact angle, single and double layer on heat transfer and flow characteristics were studied. For the wick thickness of 0.25, 0.5 and 1 mm, the 0.5 mm wick exhibits good versatility in heat transfer and flow. The porosity of 0.3 exhibits better heat transfer than that of 0.5, 0.7, 0.9. The value of the Nusselt number of the porosity of 0.3 reaches 142. For the contact Angle of 0, 30, 60, 90 degrees, 30 degrees has better heat transfer performance. Compared with single-layer wick, the double-layer wick can better promote thermal-hydraulic behavior.
AB - Previous numerical studies have focused on the temperature profiles, flow pattern, heat transfer characteristics and transient behavior of wickless heat pipes. With the increase of heat dissipated power, the heat transfer capacity of the wickless heat pipe is no longer satisfied. Therefore, the research on flow and heat transfer of wicked heat pipe is more meaningful. In this paper, the numerical model of the heat pipe evaporator with a simplified rectangular wick structure was simulated. The present work to be aimed at the numerical model investigating on possible heat transfer performance. The effects of wick thickness, wick porosity, contact angle, single and double layer on heat transfer and flow characteristics were studied. For the wick thickness of 0.25, 0.5 and 1 mm, the 0.5 mm wick exhibits good versatility in heat transfer and flow. The porosity of 0.3 exhibits better heat transfer than that of 0.5, 0.7, 0.9. The value of the Nusselt number of the porosity of 0.3 reaches 142. For the contact Angle of 0, 30, 60, 90 degrees, 30 degrees has better heat transfer performance. Compared with single-layer wick, the double-layer wick can better promote thermal-hydraulic behavior.
UR - http://www.scopus.com/inward/record.url?scp=85102690475&partnerID=8YFLogxK
U2 - 10.1088/1755-1315/680/1/012074
DO - 10.1088/1755-1315/680/1/012074
M3 - 会议文章
AN - SCOPUS:85102690475
SN - 1755-1307
VL - 680
JO - IOP Conference Series: Earth and Environmental Science
JF - IOP Conference Series: Earth and Environmental Science
IS - 1
M1 - 012074
T2 - 2021 6th International Symposium on Energy Science and Chemical Engineering, ISESCE 2021
Y2 - 22 January 2021 through 24 January 2021
ER -