Optimal ventilation mode for double fires in a typical interchange subway station

Fan Wu, Dan Wu, Yongmei Hao, Juncheng Jiang

科研成果: 期刊稿件文章同行评审

1 引用 (Scopus)

摘要

This paper investigates the optimal ventilation mode for double fires in a typical interchange subway station. Numerical simulations were carried out in a full-scale subway station with different heat release rates, ventilation modes, and fire source locations. Results demonstrate that when double fires occur, activating ventilation systems in one line may affect the smoke spread in other lines due to the existence of transfer channels. For the platform-tunnel mixed exhaust mode, when the fire size is small, the optimal TVF exhaust volume range exists. There is no optimal smoke exhaust volume for double fires with the large fire size or near the ends of the platform. Under such circumstances, the subway staff should take some measures to hinder the unwanted smoke flow path.

源语言英语
页(从-至)204-218
页数15
期刊International Journal of Ventilation
23
3
DOI
出版状态已出版 - 2024

指纹

探究 'Optimal ventilation mode for double fires in a typical interchange subway station' 的科研主题。它们共同构成独一无二的指纹。