TY - JOUR
T1 - PARAMETERS OF LIQUID COOLING THERMAL MANAGEMENT SYSTEM EFFECT ON THE Li-ION BATTERY TEMPERATURE DISTRIBUTION
AU - Ding, Yuzhang
AU - Wei, Minxiang
AU - Liu, Rui
N1 - Publisher Copyright:
© 2022 Society of Thermal Engineers of Serbia Published by the Vinča Institute of Nuclear Sciences, Belgrade, Serbia. All Rights Reserved.
PY - 2022
Y1 - 2022
N2 - In order to investigated the influence on the liquid cooling system cooling effect by changing the structural parameters, single Li-ion battery heat generation model is conducted, and used in following simulation. Subsequently, sixteen models are designed by orthogonal array, and the results are obtained by extremum difference analysis, which can quantify the influence degree, identify major and minor factors, and find the relatively optimum combination. Finally, different channel entrance lay-out is adopted to investigated. With a series of work, the effective of single battery heat generation model is proved by the discharge experiment. The coolant velocity has most evident influence on the Li-ion battery temperature rise, rectangular channel aspect ratio is second one, and the heat conducting plate thickness has the smallest influence. Similarly, for Li-ion battery temperature difference, the effect of heat conducting plate thickness and rectangular channel aspect ratio as the same, both are secondary factor, and coolant velocity is main factor. With different channel entrance lay-out, both the maximum temperatures denote a same upward trend, and better balance temperature distribution is obtained by adopt Case C system which with alternating arrange channel entrance lay-out.
AB - In order to investigated the influence on the liquid cooling system cooling effect by changing the structural parameters, single Li-ion battery heat generation model is conducted, and used in following simulation. Subsequently, sixteen models are designed by orthogonal array, and the results are obtained by extremum difference analysis, which can quantify the influence degree, identify major and minor factors, and find the relatively optimum combination. Finally, different channel entrance lay-out is adopted to investigated. With a series of work, the effective of single battery heat generation model is proved by the discharge experiment. The coolant velocity has most evident influence on the Li-ion battery temperature rise, rectangular channel aspect ratio is second one, and the heat conducting plate thickness has the smallest influence. Similarly, for Li-ion battery temperature difference, the effect of heat conducting plate thickness and rectangular channel aspect ratio as the same, both are secondary factor, and coolant velocity is main factor. With different channel entrance lay-out, both the maximum temperatures denote a same upward trend, and better balance temperature distribution is obtained by adopt Case C system which with alternating arrange channel entrance lay-out.
KW - experimental
KW - liquid cooling system
KW - numerical investigation
KW - orthogonal experimental
KW - structure optimization
UR - http://www.scopus.com/inward/record.url?scp=85124755745&partnerID=8YFLogxK
U2 - 10.2298/TSCI201019223D
DO - 10.2298/TSCI201019223D
M3 - 文章
AN - SCOPUS:85124755745
SN - 0354-9836
VL - 26
SP - 567
EP - 577
JO - Thermal Science
JF - Thermal Science
IS - 1
ER -