TY - JOUR
T1 - Probabilistic thermal analysis and phase transition temperature optimization for low-rise residential buildings with temperature-adaptive radiative cooling roofs
AU - Zou, Qingchuang
AU - Zhang, Kai
AU - Tai, Xinlong
AU - Zhang, Zihao
AU - Xiao, Fei
AU - Jiao, Siying
N1 - Publisher Copyright:
© 2024 Elsevier Ltd
PY - 2024/12/1
Y1 - 2024/12/1
N2 - This paper conducts an optimization study on the energy performance of applying temperature-adaptive radiative cooling (TARC) coatings as building roofs. To provide guidance for the application of TARC roofs, a method for determining the optimal phase transition temperature of TARC coatings for application in buildings is proposed. Then, the thermal performance of the TARC roofs is analyzed for buildings located in five different climatic zones in China based on the probability density function and cumulative distribution function. Finally, the energy efficiency of the TARC roof and the effect of the phase transition temperature on the energy savings potential of the TARC roof are discussed in detail. The results showed that the TARC roof can address the issue of increased heating loads caused by passive daytime cooling (PDRC) roofs during the heating season. Furthermore, the annual total energy savings potential of the TARC roof is 6.3–23.5 MJ/m2 for buildings located in five different climatic zones in China. In addition, the annual energy savings of buildings with TARC roofs can be further improved by 3–7% once the optimal phase transition temperature is adopted.
AB - This paper conducts an optimization study on the energy performance of applying temperature-adaptive radiative cooling (TARC) coatings as building roofs. To provide guidance for the application of TARC roofs, a method for determining the optimal phase transition temperature of TARC coatings for application in buildings is proposed. Then, the thermal performance of the TARC roofs is analyzed for buildings located in five different climatic zones in China based on the probability density function and cumulative distribution function. Finally, the energy efficiency of the TARC roof and the effect of the phase transition temperature on the energy savings potential of the TARC roof are discussed in detail. The results showed that the TARC roof can address the issue of increased heating loads caused by passive daytime cooling (PDRC) roofs during the heating season. Furthermore, the annual total energy savings potential of the TARC roof is 6.3–23.5 MJ/m2 for buildings located in five different climatic zones in China. In addition, the annual energy savings of buildings with TARC roofs can be further improved by 3–7% once the optimal phase transition temperature is adopted.
KW - Building energy savings
KW - Optimal phase transition temperature
KW - Radiative cooling
KW - Temperature-adaptive
UR - http://www.scopus.com/inward/record.url?scp=85202996074&partnerID=8YFLogxK
U2 - 10.1016/j.buildenv.2024.112053
DO - 10.1016/j.buildenv.2024.112053
M3 - 文章
AN - SCOPUS:85202996074
SN - 0360-1323
VL - 266
JO - Building and Environment
JF - Building and Environment
M1 - 112053
ER -