摘要
In order to research the tunnel fire with roof opening, the physical model of tunnel with roof opening and the mathematical model of tunnel fire were presented. The time-averaged equations for smoke mass fraction were solved for transient condition using the CFD software. Simulation results showed a relatively good agreement with experimental data, which confirmed the application of CFD code to tunnel fire with roof opening.
源语言 | 英语 |
---|---|
页(从-至) | 258-261 |
页数 | 4 |
期刊 | Dongbei Daxue Xuebao/Journal of Northeastern University |
卷 | 30 |
期 | SUPPL. |
出版状态 | 已出版 - 4月 2009 |