摘要
Composite palladium membranes can be used as a hydrogen separator because of their excellent permeability and permselectivity. The total membrane area in a hydrogen separator must be reasonably large for industrial use, and it is important that each membrane provides a large enough area. Such a demand can be well met by introducing multichannel composite membranes. In this work, a commercially available microporous ceramic filter with 19 channels was used as a membrane substrate, and the diameter of each channel was 4 mm. A uniform thin palladium layer was fabricated inside the narrow channels by using an electroless plating method, and the resulting membranes were highly permeable and selective. This membrane concept provides a high surface-to-volume ratio without causing significant pressure loss, making the hydrogen separator compact and capable. However, special attention should be paid to cleaning the membrane after electroless plating.
源语言 | 英语 |
---|---|
页(从-至) | 135-139 |
页数 | 5 |
期刊 | Journal of Power Sources |
卷 | 181 |
期 | 1 |
DOI | |
出版状态 | 已出版 - 15 6月 2008 |