TY - JOUR
T1 - Ion-exclusion chromatography determination of organic acid in uridine 5'-monophosphate fermentation broth
AU - Niu, Huanqing
AU - Chen, Yong
AU - Xie, Jingjing
AU - Chen, Xiaochun
AU - Bai, Jianxin
AU - Wu, Jinglan
AU - Liu, Dong
AU - Ying, Hanjie
PY - 2012/9
Y1 - 2012/9
N2 - Simultaneous determination of organic acids using ion-exclusion liquid chromatography and ultraviolet detection is described. The chromatographic conditions are optimized when an Aminex HPX- 87H column (300 × 7.8 mm) is employed, with a solution of 3 mmol/L sulfuric acid as eluent, a flow rate of 0.4 mL/min and a column temperature of 60°C. Eight organic acids (including orotic acid, α-ketoglutaric acid, citric acid, pyruvic acid, malic acid, succinic acid, lactic acid and acetic acid) and one nucleotide are successfully quantified. The calibration curves for these analytes are linear, with correlation coefficients exceeding 0.999. The average recovery of organic acids is in the range of 97.6% ~ 103.1%, and the relative standard deviation is in the range of 0.037% ~ 0.38%. The method is subsequently applied to obtain organic acid profiles of uridine 5'-monophosphate culture broth fermented from orotic acid by Saccharomyces cerevisiae. These data demonstrate the quantitative accuracy for nucleotide fermentation mixtures, and suggest that the method may also be applicable to other biological samples.
AB - Simultaneous determination of organic acids using ion-exclusion liquid chromatography and ultraviolet detection is described. The chromatographic conditions are optimized when an Aminex HPX- 87H column (300 × 7.8 mm) is employed, with a solution of 3 mmol/L sulfuric acid as eluent, a flow rate of 0.4 mL/min and a column temperature of 60°C. Eight organic acids (including orotic acid, α-ketoglutaric acid, citric acid, pyruvic acid, malic acid, succinic acid, lactic acid and acetic acid) and one nucleotide are successfully quantified. The calibration curves for these analytes are linear, with correlation coefficients exceeding 0.999. The average recovery of organic acids is in the range of 97.6% ~ 103.1%, and the relative standard deviation is in the range of 0.037% ~ 0.38%. The method is subsequently applied to obtain organic acid profiles of uridine 5'-monophosphate culture broth fermented from orotic acid by Saccharomyces cerevisiae. These data demonstrate the quantitative accuracy for nucleotide fermentation mixtures, and suggest that the method may also be applicable to other biological samples.
UR - http://www.scopus.com/inward/record.url?scp=84866315950&partnerID=8YFLogxK
U2 - 10.1093/chromsci/bms046
DO - 10.1093/chromsci/bms046
M3 - 文章
C2 - 22634191
AN - SCOPUS:84866315950
SN - 0021-9665
VL - 50
SP - 709
EP - 713
JO - Journal of Chromatographic Science
JF - Journal of Chromatographic Science
IS - 8
ER -