@inproceedings{dc28652603984570a02edc3c66ecc977,
title = "Corrosion failure analysis of 35CrMo bolt in wet hydrogen sulfide environment",
abstract = "Failure analysis of fracture of 35CrMo bolt was investigated. It was analyzed by means of morphology and microstructure analysis, chemical composition analysis, hydrogen content analysis, scanning electron microscope (SEM) micro-morphology of fracture surface, electronic differential system (EDS) corrosion products analysis. The results showed that the cause of fracture of 35CrMo bolt was stress corrosion cracking. Working stress of the bolt,H2S in surroundings and the high hardness of the bolt combined caused cracking of the bolt. Suitable heat treatment for the 35CrMo bolt is suggested.",
keywords = "35CrMo, Bolt, Heat treatment, Hydrogen sulfide, Stress corrosion cracking",
author = "Shi Hong-Qi and Ding Yi and Ma Li-Qun and Shen Xiao-Dong",
year = "2013",
doi = "10.4028/www.scientific.net/AMM.291-294.2605",
language = "英语",
isbn = "9783037856345",
series = "Applied Mechanics and Materials",
pages = "2605--2609",
booktitle = "Advances in Energy Science and Technology",
note = "2012 International Conference on Sustainable Energy and Environmental Engineering, ICSEEE 2012 ; Conference date: 29-12-2012 Through 30-12-2012",
}