T1 - Determination of osimertinib mesylate by HPLC
AU - Zhou, Ping
AU - Li, Li
AU - Wu, Lulu
AU - Cu, Chenhao
AU - Tian, Huimin
AU - Ren, Xiaoming
AU - Zhang, Haijun
AU - Wu, Jiaquan
PY - 2017/6
Y1 - 2017/6
N2 - To establish an HPLC method to determine osimertinib mesylate, Agilent ZORBAX Eclipse Plus Clg column (4.6 mm x 250 mm, 5 jjliii) was used with a mobile phase consisting of methanol-buffer solution (20 mmol/L NaH2P04, pH 3.0 adjusted with 85% H3P04) (50 : 50) at the flow rate of 1.0 mL/min. The detection wavelength was 210 nm, and the column temperature was kept at 35 The calibration curve was liner over the range from 50% to 150% of determination concentration (0. 201 1-0. 603 2 mg/mL, r =0. 999 9). The limit of quantitation ( LOQ) and limit of detection ( LOD) were 0. 32 p.g/mL and 0. 08 fig/mL, respectively. The contents of osimertinib mesylate in samples were 100. 1%,99. 5% and 99. 7%. Good chromatographic separation of osimertinib mesylate and its related substances, including synthetic impurities and degradation products, were obtained. The established HPLC method is specific, accurate, simple and durable, and could be used for the determination of osimertinib mesylate.
AB - To establish an HPLC method to determine osimertinib mesylate, Agilent ZORBAX Eclipse Plus Clg column (4.6 mm x 250 mm, 5 jjliii) was used with a mobile phase consisting of methanol-buffer solution (20 mmol/L NaH2P04, pH 3.0 adjusted with 85% H3P04) (50 : 50) at the flow rate of 1.0 mL/min. The detection wavelength was 210 nm, and the column temperature was kept at 35 The calibration curve was liner over the range from 50% to 150% of determination concentration (0. 201 1-0. 603 2 mg/mL, r =0. 999 9). The limit of quantitation ( LOQ) and limit of detection ( LOD) were 0. 32 p.g/mL and 0. 08 fig/mL, respectively. The contents of osimertinib mesylate in samples were 100. 1%,99. 5% and 99. 7%. Good chromatographic separation of osimertinib mesylate and its related substances, including synthetic impurities and degradation products, were obtained. The established HPLC method is specific, accurate, simple and durable, and could be used for the determination of osimertinib mesylate.
KW - Determination
KW - HPLC
KW - Osimertinib mesylate
KW - Related substances
UR - http://www.scopus.com/inward/record.url?scp=85027530717&partnerID=8YFLogxK
U2 - 10.11665/j.issn.1000-5048.20170312
DO - 10.11665/j.issn.1000-5048.20170312
M3 - 文章
AN - SCOPUS:85027530717
SN - 1000-5048
VL - 48
SP - 322
EP - 327