TY - JOUR
T1 - Ratiometric Fluorescent Quantum Dot-Based Biosensor for Chlorothalonil Detection via an Inner-Filter Effect
AU - Sheng, Enze
AU - Lu, Yuxiao
AU - Tan, Yuting
AU - Xiao, Yue
AU - Li, Zhenxi
AU - Dai, Zhihui
N1 - Publisher Copyright:
Copyright © 2020 American Chemical Society.
PY - 2020/3/17
Y1 - 2020/3/17
N2 - A new sensitive sensor for detecting chlorothalonil (CHL) based on the inner-filter effect (IFE) between gold nanoparticles (AuNPs) and ratiometric fluorescent quantum dots (RF-QDs) was developed. Here, RF-QDs were designed by two different color CdTe QDs. Based on the IFE, the AuNPs can quench the fluorescence of the RF-QDs. Because of the electrostatic attraction between protamine (PRO) and the AuNPs, the PRO can restore fluorescence effectively. Papain (PAP) can easily hydrolyze PRO and causes the quench of fluorescence quenching. The addition of CHL can inhibit PAP activity and restore the fluorescent signal. Through the characterization of the structural changes of PAP, the inhibition and mechanism of CHL on PAP activity were studied. The ability of CHL to inhibit PAP activity was evaluated by measuring the fluorescence of the RF-QDs. Under the optimal conditions, this sensing platform shows a response to CHL in the range of 0.34-2320 ng/mL and a detection limit of 0.0017 ng/mL. Based on the CHL inhibition of PAP activity, the RF-QDs showed good selectivity for CHL. The practical application of the proposed system was demonstrated by detecting CHL in food and environmental samples with satisfying results.
AB - A new sensitive sensor for detecting chlorothalonil (CHL) based on the inner-filter effect (IFE) between gold nanoparticles (AuNPs) and ratiometric fluorescent quantum dots (RF-QDs) was developed. Here, RF-QDs were designed by two different color CdTe QDs. Based on the IFE, the AuNPs can quench the fluorescence of the RF-QDs. Because of the electrostatic attraction between protamine (PRO) and the AuNPs, the PRO can restore fluorescence effectively. Papain (PAP) can easily hydrolyze PRO and causes the quench of fluorescence quenching. The addition of CHL can inhibit PAP activity and restore the fluorescent signal. Through the characterization of the structural changes of PAP, the inhibition and mechanism of CHL on PAP activity were studied. The ability of CHL to inhibit PAP activity was evaluated by measuring the fluorescence of the RF-QDs. Under the optimal conditions, this sensing platform shows a response to CHL in the range of 0.34-2320 ng/mL and a detection limit of 0.0017 ng/mL. Based on the CHL inhibition of PAP activity, the RF-QDs showed good selectivity for CHL. The practical application of the proposed system was demonstrated by detecting CHL in food and environmental samples with satisfying results.
UR - http://www.scopus.com/inward/record.url?scp=85082146899&partnerID=8YFLogxK
U2 - 10.1021/acs.analchem.9b05199
DO - 10.1021/acs.analchem.9b05199
M3 - 文章
C2 - 32050759
AN - SCOPUS:85082146899
SN - 0003-2700
VL - 92
SP - 4364
EP - 4370
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 6
ER -