TY - JOUR
T1 - Research on seismic performance of framework with new SIP filled wallboard
AU - Wang, Shuguang
AU - Sun, Wei
AU - Liu, Weiqing
AU - Du, Dongsheng
AU - Mao, Rongfang
PY - 2013/3
Y1 - 2013/3
N2 - This article describes the test procedure of the seismic performance of reinforced concrete frame structure with the new type of SIP filled wallboard, including four spcimens of low-cyclic loading test, which are a specimen of empty framework, a specimen of framework with the new type SIP wallboard and two specimens of framework with the new type SIP filled wallboard that has a hole in different location, and the reinforced concrete frame design of the four specimens is the same. Through comparison of the seismic performance of four frame specimens, the seismic performance of frame structure with the new type SIP filled wallboard was obtained. The experimental phenomena and results show that the seismic performance in respect of ductility, strength and energy dissipation of the frame structure with the new type SIP filled wallboard is favorable, and the way of the connection between the new wallboard and the frame structure is reliable.
AB - This article describes the test procedure of the seismic performance of reinforced concrete frame structure with the new type of SIP filled wallboard, including four spcimens of low-cyclic loading test, which are a specimen of empty framework, a specimen of framework with the new type SIP wallboard and two specimens of framework with the new type SIP filled wallboard that has a hole in different location, and the reinforced concrete frame design of the four specimens is the same. Through comparison of the seismic performance of four frame specimens, the seismic performance of frame structure with the new type SIP filled wallboard was obtained. The experimental phenomena and results show that the seismic performance in respect of ductility, strength and energy dissipation of the frame structure with the new type SIP filled wallboard is favorable, and the way of the connection between the new wallboard and the frame structure is reliable.
KW - Low cyclic loading test
KW - New type SIP filled wallboard
KW - Reinforced concrete frame structure
KW - Seismic performance
UR - http://www.scopus.com/inward/record.url?scp=84877322615&partnerID=8YFLogxK
M3 - 文章
AN - SCOPUS:84877322615
SN - 1007-6069
VL - 29
SP - 108
EP - 113
JO - World Earthquake Engineering
JF - World Earthquake Engineering
IS - 1