Fire smoke control in different structures of subway station

De Zhi Zhu, Jun Cheng Jiang

科研成果: 期刊稿件文章同行评审

1 引用 (Scopus)

摘要

The platform layer of the subway station was a confined space, so different structures, such as the location and structure of stairs, the installation of platform edge door, have vital influence on the subway station fires. The fire was located on the platform layer of the train arranges on to simulate the smoke diffusion by CFD. The influence of different structures on smoke control was compared. Results indicate that different structures have different influence on the smoke flowing. The efficiency of exhaust was raised by 22.3%. Comparing the worst and the best situation and the temperature difference reaches 53K. The smoke was restrained in the railway space after installing the platform door to reduce the damage of high temperature smoke and raise the efficiency of exhaust. It's feasible to design the structures for optimizing the smoke control model by designing the location, the structure of stairs and the installation of platform edge door.

源语言英语
页(从-至)681-686
页数6
期刊Jiefangjun Ligong Daxue Xuebao/Journal of PLA University of Science and Technology (Natural Science Edition)
9
6
出版状态已出版 - 12月 2008

指纹

探究 'Fire smoke control in different structures of subway station' 的科研主题。它们共同构成独一无二的指纹。

引用此