New estimation of the dosage of scale inhibitor in the cooling water system

Jiang Jiaomei, Xu Yanhua

科研成果: 期刊稿件文章同行评审

3 引用 (Scopus)

摘要

In the cooling water system, excessive use of organic phosphate scale inhibitors is harmful to environment. Reducing the dosage of the organic phosphate scale inhibitor is important. A self-made jacketed crystallizer was used in this experiment. The critical pH values have been determined in cooling water systems with series of Ca2+ concentrations by adding different concentration of the scale inhibitor ATMP (Amino Trimethylene Phosphonic Acid) according to the calcium carbonate Metastable zone theory. A model equation at 45 °C and pH=9 was proposed to estimate the lowest dose of the scale inhibitor ATMP. The measured pH value was approximate to the expected pH value in two cooling water systems through verification test.

源语言英语
页(从-至)1881-1885
页数5
期刊E-Journal of Chemistry
8
4
DOI
出版状态已出版 - 10月 2011